Aprašymas
Table 1 Line Mode Specifications |
||||
INVERTER MODEL |
1.0KW 12V |
1.5KW 24V |
24V 3.2KVA 3KW |
12V 2KVA 1.6KW |
Input Voltage Waveform |
Sinusoidal (Utility or Generator) |
|||
Nominal Input Voltage |
230Vac |
|||
Max AC Input Voltage |
300Vac |
|||
Nominal Input Frequency |
50Hz/60Hz(Auto detection) |
|||
Output Short Circuit Protection |
Circuit Breaker |
|||
Efficiency (Line Mode) |
>95%(Rated R load,battery full charged |
|||
Transfer Time |
10ms Typical (UPS); 20ms Typical (Appliances) |
|||
Tabke 2 Inverter Mode Specifications |
||||
INVERTER MODEL |
1.0KW 12V |
1.5KW 24V |
24V 3.2KVA 3KW |
12V 2KVA 1.6KW |
Rated Output Power |
1000VA/1000W |
1500VA/1500W |
3200VA/3000W |
2000VA/1600W |
Output Voltage Waveform |
Pure Sine Wave |
|||
Output Voltage Regulation |
230Vac±5% |
|||
Output Frequency |
50Hz |
|||
Peak Efficiency |
0.94 |
|||
Overload Protection |
5s@≥150% Ioad; 10s@≤100%〜150% Ioad |
|||
Surge Capacity |
2*rated power for 5 seconds |
|||
Nominal DC Input Voltage |
12Vdc |
24Vdc |
24Vdc |
12Vdc |
Cold Start Voltage |
11.5Vdc |
23.0Vdc |
23.0Vdc |
11.5Vdc |
High DC Recovery Voltage |
15.5Vdc |
31Vdc |
32Vdc |
14.0Vdc |
High DC Cut-off Voltage |
16.0Vdc |
32Vdc |
33Vdc |
16.0Vdc |
No Load Power Consumption |
<28W |
<28W |
<35W |
<25W |
Table 3 Charge Mode Specifications |
||||
Utility Charging Mode |
||||
INVERTER MODEL |
1.0KW 12V |
1.5KW 24V |
24V 3.2KVA 3KW |
12V 2KVA 1.6KW |
Charging Algorithm |
3-Step |
|||
AC Charging Current(Max) |
40Amp (V/p=230Vac) |
60Amp (@V /P=230vac) |
||
Floating Charging Voltage |
13.5Vde |
27Vd |
27vdc |
13.5vdc |
MPPT Solar Charging Mode |
||||
INVERTER MODEL |
1.0KW 12V |
1.5KW 24V |
24V 3.2KVA 3KW |
12V 2KVA 1.6KW |
Max.PV Array Power |
600W |
1200W |
3000W |
2000W |
PV Array MPPT Voltage Range |
20~150Vdc |
30~150Vde |
30~400vdc |
|
Max.PV Array Open Circuit Voltage |
150Vdc |
400vdc |
||
Max(AC+Solar)Charging current |
80Amp |
Item View:
24V 3.2KVA 3KW; 12V 2KVA 1.6KW